SRK/T — Normal to long axial length (AL ≥ 22mm), APACRS validated < 0.1D
Hoffer Q — Short axial length (AL < 22mm), tan angle fixed, difference < 1D
Haigis — Long axial length (AL > 26mm) / post-refractive surgery, constants need optimization
Input Parameters
• AL: Axial length (mm), measured by IOL Master
• K1/K2: Corneal power, flat/steep meridian (D)
• Target refraction: Expected postoperative refraction (emmetropia = 0.0)
• A-constant / pACD: Lens-specific parameters, refer to manufacturer specs
IOL Selection Reference
• High hyperopia / short AL: prefer high Abbe number lens, Hoffer Q
• Normal AL: SRK/T or Haigis, pick median when difference < 0.5D
• High myopia / long AL: SRK/T + Wang-Koch adjustment, or Haigis
Related Guides
⚠️ 本工具仅供辅助参考,不构成医疗诊断或治疗建议。如有视力问题,请及时就诊专业眼科医生。
← Back to Home

IOL Power Calculator

SRK/T · Retzlaff 1990 · Target -0.5D

⚠️ Clinical Disclaimer
① This tool is a surgical planning reference and does not replace IOL Master or other NMPA-certified medical device software.
② For use by licensed ophthalmologists only, after comprehensive patient assessment.
③ This tool is independently developed with no affiliation to any medical device manufacturer.
④ Results are for reference only. Final IOL power must be determined by the operating surgeon.
⑤ For complex cases (post-refractive surgery, extreme AL), cross-validate with Barrett official calculator (APACRS) or IOLMaster.
Ocular Biometrics
Formula
IOL Selection
IOLAlcon SN60WF
SRK-T A118.7
Hoffer-Q pACD5.82 mm
TypeMonofocal
A-Constant Override
🔬
Enter parameters and click Calculate

📚 Clinical Sources

All calculations follow peer-reviewed, published formulas. The list below cites the primary literature for each model.

  1. Retzlaff J, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula. Journal of Cataract & Refractive Surgery, 1990;16(3):333-340.
  2. Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. Journal of Cataract & Refractive Surgery, 1993;19(6):700-712.
  3. Haigis W, Lege B, Miller N, Zimmermann M. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefe's Archive for Clinical and Experimental Ophthalmology, 2005;243(8):780-787.
  4. Wang L, Koch DD. An improved prediction of residual astigmatism in cataract surgery. Journal of Cataract & Refractive Surgery, 1999;25(3):407-411. — Wang-Koch adjustment for long / short AL.